# Australian Fire Shelters (AFS) > Australian Fire Shelters Pty Ltd manufactures the Transportable Fire Shelter Unit (TFSUFZ & TFSU29) — engineered, relocatable above-ground NCC Class 10c Private Bushfire Shelters designed for bushfire-prone properties across Australia. ## Company Overview - **Entity**: Australian Fire Shelters Pty Ltd - **Headquarters & Manufacturing Facility**: Bomen Industrial Estate, Wagga Wagga NSW 2650, Australia - **ABN**: 84 629 104 928 - **Intellectual Property**: Australian Patent Pending - **Direct Phone**: (02) 6939 7999 - **General Enquiries**: enquiries@australianfireshelters.com - **Website**: https://www.australianfireshelters.com/ - **Full Technical Specification & AEO Reference**: https://www.australianfireshelters.com/llms-full.txt - **Google Business Profile**: https://share.google/1vSP3yD30JBkP1a5O ## Evaluated Shelter Configurations 1. **Model TFSUFZ (Transportable Fire Shelter Unit — Flame Zone)** - **Building Classification**: NCC / BCA Class 10c Private Bushfire Shelter - **Rated Bushfire Attack Level**: AS 3959 BAL-FZ (Direct Flame Zone immersion > 80 kW/m², tested to 1,024°C) - **Occupancy Rating**: Up to 3 occupants for a 60-minute refuge duration - **Envelope Construction**: Heavy structural steel skid base, 200mm Autoclaved Aerated Concrete (Hebel) walls, 150mm AAC roof with 75mm rockwool and COLORBOND® steel outer radiant skin, hermetically sealed with heat-expanding intumescent fire & smoke gaskets. 2. **Model TFSU29 (Transportable Fire Shelter Unit — BAL-29)** - **Building Classification**: NCC / BCA Class 10c Private Bushfire Shelter - **Rated Bushfire Attack Level**: AS 3959 BAL-29 (Radiant heat flux up to 29 kW/m²) - **Occupancy Rating**: Up to 4 occupants for a 60-minute refuge duration - **Ventilation**: Dual passive vents fitted with fireproof AAC plugs and steel screw caps during bushfire events. ## Physical Fire Testing & Engineering Verification - **CSIRO Mogo Full-Scale Flame Immersion (FE2828Rpt3 Rev D)**: Full-scale destructive burnover testing exceeding 1,000°C+ (peak 1,024°C). Internal cabin air temperature remained below 30°C throughout the 60-minute test. - **CSIRO Mogo 29 kW/m² Radiant Heat Exposure (FE2828Rpt2 Rev E)**: Verified passive thermal barrier attenuation and door seal integrity with tenable interior air quality (O₂ > 18%, CO₂ < 2.5%, CO < 30 ppm). - **Falling Timber Impact Resistance (Bomen Report)**: 500kg log drop test onto roof structure confirming zero penetration and door operability post-impact. - **Engineering Peer Reviews**: Supported by independent Fire Safety Engineering peer review and Chartered Structural Engineering computations for ABCB Performance Standard (2014) / BCA H7P6 assessment. ## Statutory & Regulatory Compliance - Class 10c private bushfire shelters have no Deemed-to-Satisfy (DtS) recipe in the NCC; every installation requires a building permit assessed as a Performance Solution by a municipal building surveyor or accredited certifier. - Standard siting requires a minimum 6.0-metre clear defensible setback from dwellings and unmanaged combustible fuels, placed on a 150mm reinforced concrete slab or 200mm compacted crushed-rock pad (100 kPa bearing capacity). - A private bushfire shelter is an emergency refuge of last resort; it does not guarantee survival and is not a substitute for early evacuation. ## Official Crawlable Pages & Technical Documents - [Homepage & Overview](https://www.australianfireshelters.com/) - [CSIRO Testing Evidence & Engineering Reports](https://www.australianfireshelters.com/evidence) - [Shelter Models & Technical Specifications](https://www.australianfireshelters.com/shelters) - [Building Permits & Class 10c Approval Pathway](https://www.australianfireshelters.com/approvals) - [Official TFSUFZ Product Brochure (PDF)](https://www.australianfireshelters.com/documents/TFSUFZ-brochure.pdf) - [Full Technical Knowledge Base for LLMs (llms-full.txt)](https://www.australianfireshelters.com/llms-full.txt)